Sauna glossary
By the Best Sauna Picks team · Updated · How we research
A sauna listing mixes words from Finland, from electricians, from lumber yards and from cold plunge makers, and each one changes what you buy or how safely you use it. This glossary defines 57 of them in plain American English, grouped by what they affect, with a real number wherever one helps and a source wherever the number touches health, wiring or safety. Each entry links to the guide that goes deeper, so you can look a word up, then check what it means for your own cabin, wiring or tub. If you are starting from zero, read what a sauna is first, then come back to look up a word.
Heat and sauna types
Dry sauna
A dry sauna is a traditional room heated by an electric or wood stove to about 150 to 195°F, the range Cleveland Clinic gives for traditional rooms. Humidity stays low until someone adds water. It is the room most long-term studies describe. See what a traditional dry sauna is and dry vs wet sauna. For what the heat does for you, read dry sauna benefits.
Wet sauna
A wet sauna is a traditional sauna where you ladle water onto hot stones, so humidity jumps for a minute or two while the air stays at 150 to 195°F. It is not a steam room, which is a different room with a generator. A heater that cannot take water cannot make one. The details are in wet sauna and traditional steam sauna.
Löyly
Löyly is the Finnish word for the burst of steam released when water hits heated stones. UNESCO describes it in its listing of Finnish sauna culture, which counts about 3.3 million saunas for roughly 5.5 million people. Stones above 212°F flash the water to steam. Pour slowly, on the stones only. See wet sauna and traditional steam sauna.
Traditional sauna
A traditional or Finnish sauna heats the air with a stove and stones, usually electric at home, and lets you add steam. Finnish research describes rooms at 80 to 100°C (176 to 212°F), according to the 2018 Mayo Clinic Proceedings review by Laukkanen and colleagues, but those are research limits, not targets. See sauna temperature and the traditional sauna guide.
Infrared sauna
An infrared sauna is an electric cabin with panels that radiate infrared light and no stove, stones or steam. Cleveland Clinic puts the air at 110 to 135°F, cooler than a traditional room, and many models plug into a 120 V outlet. Read what an infrared sauna is and infrared vs traditional sauna.
Far infrared
Far infrared is the long-wavelength end of infrared light, felt as gentle heat rather than seen. Makers quote 8 to 15 µm for carbon panels, while the CIE scheme defines far infrared as 3 to 100 µm and ISO 20473 as 50 to 1,000 µm. A panel at 10 µm is far infrared under one scheme and mid infrared under the other. See the far infrared sauna guide.
Near infrared
Near infrared is the short-wavelength end of the band, next to visible red. In sauna listings it usually means LEDs at about 810 to 850 nm, which sit in cabins whose heaters run separately at 110 to 170°F. Check the maker for the exact range. Read red light therapy in a sauna and the red light sauna guide.
Mid infrared
Mid infrared sits between near and far, and the line between the two is drawn differently by different standards. Full spectrum cabins add mid and near infrared heaters to the far infrared panels. The JNH Arki Duo, for instance, lists 8 far and mid infrared heaters beside its red light emitters. See the 2 person infrared sauna guide.
Full spectrum
A full spectrum infrared sauna layers near and mid infrared on top of far infrared heaters. More bands mean more heaters and watts, never more floor. The Sun Home Equinox 2-Person uses 2 full spectrum and 4 far infrared heaters and draws 1,880 W on a 120 V, 20 A circuit, according to Sun Home. See the full spectrum infrared sauna guide.
Steam room
A steam room is a sealed, wet room at about 100 to 120°F with humidity near 100 percent, per WebMD. Sessions run 5 to 10 minutes, against 15 to 20 in a sauna. At home it needs a steam generator and waterproof surfaces. Read sauna vs steam room for the comparison and home steam room to plan one. For what the room does for you, see steam room benefits.
Hammam
A hammam is a Turkish-style steam bath: wet, low-temperature heat in a tiled room. At home it is the same product as a steam room, with the same plumbing and waterproofing, and not a hot dry cabin. A portable steam tent runs 110 to 145°F, below many hammam rooms. See home steam room and the portable steam sauna guide.
Banya
A banya is the Russian cousin of the wet sauna: a hot room where stones are doused with water, often shared in rounds. At home the closest match is a traditional stove sauna that can take water. Check the heater maker before you ladle. See wet sauna and traditional steam sauna.
Steam shower
A steam shower is a closed shower enclosure fed by a steam generator. The generator is sized to the cubic feet of the enclosure and the wall material, and its label gives kW and amps. It is a wet room in a shower footprint, not a sauna. See the steam shower guide and steam shower generator sizing.
Heaters, stoves and electricity
Kilowatt (kW)
A kilowatt is 1,000 watts, the unit a sauna heater is rated in. A 6 kW heater suits 170 to 300 cu ft and draws 25 A at 240 V; a 4.5 kW heater suits rooms under about 210 cu ft. Compare maker ranges, not rules of thumb. Use the sauna heater size calculator and the sauna heater guide.
Effective volume
Effective volume is your cabin's length times width times height, plus about 4 cu ft for each square foot of glass, tile or stone, because those surfaces pull heat out. Harvia counts 1.2 cubic meters per square meter, per its heater power guidance. A 6 x 5 x 7 ft room with a 10 sq ft glass door works out to 250 cu ft. See the sauna heater size calculator.
Amps
Amps equal watts divided by volts. A 6 kW heater draws 6,000 / 240 = 25 A, a 4.5 kW heater 18.75 A, an 8 kW heater 33.3 A and a 9 kW heater 37.5 A. On 120 V the current doubles. The installation falls under NFPA 70. See sauna electrical requirements.
120 V and 240 V
Household outlets give 120 V; a stove heater of 4.5 kW or more needs a 240 V circuit, because at 120 V it would draw 37.5 A, far above a 15 or 20 A circuit. Plug-in infrared cabins and small heaters of about 2 kW or less run on 120 V. Pick by the circuit you have. See 120V sauna heater guide and 240V sauna heater guide.
Dedicated circuit
A dedicated circuit is a breaker that feeds the sauna and nothing else. Every cabin on our infrared pages asks for one: the Equinox 2-Person wants a dedicated 20 A circuit, per Sun Home's electrical guide, and a hair dryer on the same breaker can trip it. See sauna electrical requirements.
125 percent rule
The National Electrical Code treats a continuous load as 125 percent of its current when sizing the breaker. For a 6 kW heater, 25 A times 1.25 is 31.3 A, so the next size up is 35 A, while one Harvia manual pairs 6 kW with a 30 A breaker. The manual and your electrician decide. See NFPA 70 and Article 424.
Wire gauge (AWG)
AWG is the wire size; a lower number is thicker wire. HUUM lists 10 AWG on a 30 A fuse for its 6 kW Drop and 8 AWG for the 9 kW on a 50 A fuse, and Finnleo requires copper wire only. Never copy a gauge from a web page: the run length and the manual set it. See sauna electrical requirements.
GFCI
A ground-fault circuit interrupter cuts the power when current leaks to ground. Plunge ships its All-In with a 7 ft GFCI plug cord, and BlueCube's 20 A Deep includes one. A GFCI protects against shock but does not make water and mains power safe, so have an electrician do any wiring. See cold plunge with chiller.
NFPA 70 (National Electrical Code)
NFPA 70 is the National Electrical Code, the US model for wiring, adopted and amended locally. Article 424 covers fixed electric heating equipment. A code reference on a web page is no substitute for your inspector and a licensed electrician. See NFPA 70 and sauna electrical requirements.
Sauna stones
Sauna stones sit on or around the heater, store heat and turn water into steam. A Harvia KIP holds 44 lb; the Harvia M3 wood stove holds 66.2 lb. HUUM asks for rock of 5 to 10 cm (2 to 4 in). Stack loosely so air rises through the pile, and never run a heater without rocks. See the sauna rocks and stones guide and Harvia's stone care guide.
Kiuas
Kiuas is the Finnish word for the sauna heater or stove together with its stones. Shoppers meet it on imported electric heaters and wood stoves. It is the part that makes both the dry heat and the löyly, so its kW rating and stone load matter more than its looks. See Finnish sauna heater guide and Harvia saunas and heaters.
Wood-burning stove
A wood-burning sauna stove heats the stones with logs and needs a flue, clearances and a hearth instead of a circuit. The Harvia M3 covers 212 to 459 cu ft, weighs 99.2 lb and holds 66.2 lb of stones, per Harvia. It suits cabins with no 240 V line. See the wood burning sauna stove guide.
Heat-up time
Heat-up time is how long a cabin takes to reach its working temperature. Makers rarely publish it. Sun Home gives a preheat of 15 to 20 minutes for the Equinox, and cold weather adds time. Treat any figure without a named test as an estimate and time your own cabin. See how long a sauna takes to heat up.
Wood and construction
Western red cedar
Western red cedar is the classic sauna wood. It has the lowest conductivity of the common choices, 0.10 W/mK at 12 percent moisture, according to the USDA Wood Handbook, so boards stay comfortable to touch, and it resists decay. It smells like a cedar chest. See the cedar sauna guide and the wood for a sauna guide.
Hemlock
Hemlock is a pale softwood that is nearly scent-free, so it suits anyone bothered by cedar's smell. Cedar shrinks 5.0 percent tangentially from green to dry and hemlock 7.8, per the Wood Handbook figures on our wood page. The Redwood Outdoors Haven uses heat-treated hemlock indoors. See the wood for a sauna guide and cedar vs hemlock sauna.
Thermowood
Thermowood is lumber cooked in steam at high heat, with no chemicals added, so it holds less resin and swells less with moisture. The International ThermoWood Association names class S, treated at 190°C, for sauna interiors and benches; class D is treated at 212°C. It suits yards well. See the wood for a sauna guide and the outdoor sauna guide.
Vapor barrier
A vapor barrier is a foil layer on the warm side of the insulation that keeps humid air out of the wall. Lap the seams 4 to 6 in and tape every cut, including those for vents and wiring. A missing or torn barrier is one of the three details that decide a build, with ventilation and wiring. See how to build a sauna and sauna plans.
R-value
R-value measures how well insulation resists heat flow; a higher number insulates better. For a mild climate, Haven of Heat's chart calls for R-13 in the walls and R-19 in the ceiling; a colder zone needs more. Insulation also cuts the heater size you need. See how to build a sauna.
Rough opening
A rough opening is the framed hole a door or vent is set into, a little larger than the unit. Finlandia gives 26 x 82 in for its standard 24 x 80 in door, and its vents ask for 4 x 10 in openings. Measure the manufacturer's figure, not the door. See the sauna door guide and the indoor sauna kits guide.
Bench height
Bench height sets how hot you sit, because heat rises. Haven of Heat puts the upper bench 36 to 42 in below the ceiling, at least 18 in deep, while Harvia gives 1,100 to 1,200 mm (43 to 47 in); the sources differ. Almost Heaven's Appalachia has a 24 in upper and 19 in lower bench. See sauna design ideas and sauna plans.
Ventilation
Ventilation is the fresh air that keeps a sauna comfortable. Sun Home advises 4 to 6 air changes an hour with a 4 to 6 in inlet and outlet. Follow your heater manual's vent drawing and seal the cuts through the foil. Leave the door ajar afterward so the wood dries. See how to build a sauna.
Infrared heaters and light
Carbon heater
A carbon heater is a panel of carbon material that radiates far infrared. Sun Home puts the surface of a carbon panel at 150 to 200°F (65 to 93°C). It is a flat panel that covers a wall. See the far infrared sauna guide and infrared sauna heaters and panels.
Ceramic heater
A ceramic heater is a rod or element that radiates infrared and runs hotter than a carbon panel: Sun Home puts a ceramic rod at 350 to 500°F (175 to 260°C). It warms a smaller area more intensely, so placement matters. See the far infrared sauna guide and the infrared sauna guide.
EMF
EMF stands for electric and magnetic fields, which every powered heater gives off. Cabins differ widely, and makers publish figures from under 1 mG to "under 8 mG." Ask for a seated reading and the lab that measured it, not just the word "low." See infrared sauna EMF explained and low EMF infrared sauna guide.
Milligauss (mG)
A milligauss is the unit makers use for magnetic field strength. Sun Home claims 0.5 mG seated on its Equinox, and JNH cites Vitatech report VTE-3155 for 0.02 mG seated and 0.32 mG at the heater panel on the Arki. Compare readings taken at the same spot. See infrared sauna EMF explained.
Red light therapy
Red light therapy in a sauna means LEDs at about 630 to 670 nm (red) and 810 to 850 nm (near infrared). Harvard Health calls it photobiomodulation. The best evidence comes from skin and pain trials that did not use a sauna. See red light therapy in a sauna.
mW/cm²
Milliwatts per square centimeter measures how much red light lands on your skin. JNH calls its 40 to 60 mW/cm² an estimate and says the cabin has not been evaluated in clinical trials. Peak publishes readings at 6, 12 and 24 in on the Fuji. A cabin that gives no reading cannot be compared. See the red light sauna guide.
Cold plunge
Cold plunge
A cold plunge is a tub of cold water you sit in for a few minutes. Cleveland Clinic suggests 50 to 59°F (10 to 15°C) for the first weeks and never below 40°F (4°C). A chiller can go to 28 to 37°F, which is its floor and not your goal. See cold plunge temperature and the cold plunge tub guide. For what it does for you, read cold plunge benefits.
Ice bath
An ice bath is a cold plunge cooled with bagged ice instead of a machine. Our arithmetic: about 103 lb of ice takes 100 gallons from 70 to 50°F. It costs nothing to set up and a bag run every session, which is why many people move to a chiller. See DIY ice bath and stock tank cold plunge and cold plunge temperature.
Chiller
A chiller is the refrigeration unit that cools and holds the water, so a plunge can run daily without ice. The Plunge All-In pairs a 0.75 HP chiller with 105 gallons, holds 37°F in 120°F air and cools 10 to 12°F per hour, per Plunge. Tubs run on 120 V, 12 to 20 A. See cold plunge with chiller.
HP (horsepower)
HP is the chiller's motor power, 0.5 to 1.5 HP among the tubs we compared where a maker publishes it. More horsepower cools faster or handles warmer air, but it also draws more current. Check the lowest setpoint and the cooling rate in degrees per hour, not horsepower alone. See cold plunge with chiller and the cold plunge tub guide.
Ozone
Ozone is a gas made by an onboard generator to sanitize plunge water. One maker lists ozone and a pump that clean the whole volume every 15 minutes. It reduces chemistry but does not end draining: a tub with ozone still needs a water change schedule and a smell test. See cold plunge water care and cleaning.
UV-C
UV-C is ultraviolet light that kills germs passing the lamp but leaves no residual sanitizer in the water. Sun Home asks you to clean the quartz sleeve monthly and replace the bulb every 4 to 6 months if its intensity drops. Pair it with a filter. See cold plunge water care and cleaning.
Micron rating
A micron rating says the smallest particle a filter catches, in millionths of a meter; a lower number filters finer. Redwood, the Plunge Pro Chiller and BlueCube list 20 micron cartridges, and an ice-only barrel can use a 10 to 20 micron cartridge with a sanitizer. Rinse or replace on the maker's schedule. See cold plunge water care and cleaning.
ppm and pH
A ppm is one milligram per liter, so the dose scales with water volume. CDC's hot tub guidance sets free chlorine at 3 to 10 ppm and pH at 7.2 to 7.8; Sun Home cites 1 to 3 ppm chlorine for plunges. CDC publishes no cold plunge target. See cold plunge water care and cleaning.
Health
Core temperature
Core temperature is the temperature of your vital organs, not your skin. Cold water lowers it, and Cleveland Clinic says a long stay can bring shivering, confusion and even unconsciousness. MedlinePlus puts the emergency line at below 95°F. Time every plunge. See are cold plunges and ice baths safe.
Hypothermia
Hypothermia is a body temperature that has fallen below 95°F, per MedlinePlus. In a cold plunge the warning signs are shivering that will not stop, confusion and clumsiness. Get out and warm up at once, and ask your doctor first if you have a heart condition. See how long to cold plunge.
Hyperthermia
Hyperthermia is a dangerously high body temperature. Makers warn that alcohol, drugs and medication can greatly raise the risk of fatal hyperthermia, and that pregnant women and people in poor health should see a physician first, per the Finnleo heater manual. Dizziness and cramps can signal heat exhaustion. See how to use a sauna.
Contrast therapy
Contrast therapy alternates heat and cold: sauna at 150 to 185°F, then cold water at 37 to 59°F, repeated. At home it means two machines on separate circuits. The research is limited, so ask your doctor first if you have a heart condition or take medication. See cold plunge and sauna contrast therapy.
Observational study
An observational study follows people who made their own choices and finds associations, not proof of cause. In the 2015 JAMA Internal Medicine study of 2,315 Finnish men, those using a sauna 4 to 7 times a week had a lower rate of sudden cardiac death than those using one once a week (hazard ratio 0.37). Read such results as "associated with." See sauna health studies.
Safety and certification
CPSC recall
A CPSC recall is a notice from the US Consumer Product Safety Commission that a product is a hazard. Eight sauna recalls were in its database on November 17, 2026, including 41,580 Sauna360 infrared saunas (CPSC 26-784) and 78,000 Lifepro BioRemedy blankets (CPSC 26-036). Stop using a recalled unit. See sauna recalls and CPSC.
UL 875
UL 875, Electric Dry-Bath Heaters, is the US safety standard for sauna heaters; its current edition is dated July 2024, per the ANSI webstore. The standard is paid, so we have not read its temperature limits. Heater manuals state the limits that apply. See sauna temperature and the sauna heater guide.
UL listing
A UL listing means UL LLC, a lab on OSHA's list of nationally recognized testing laboratories, tested the product to a safety standard. It lowers risk but does not prevent a later recall: Sauna360 products were recalled after sale for panel faults. See sauna recalls.
ETL listing
ETL is the mark of Intertek, another lab on OSHA's list. Intertek says an ETL Listed mark means independent testing to the applicable standards, and that building inspectors accept it as they accept other recognized marks. Some cabins show no ETL mark on the page, so look for the listing. See sauna recalls and the indoor sauna guide.
Sources
- Cleveland Clinic: sauna benefits
- Cleveland Clinic: infrared sauna benefits
- Cleveland Clinic: what to know about cold plunges
- UNESCO: sauna culture in Finland
- Laukkanen and colleagues, Mayo Clinic Proceedings, 2018
- Laukkanen and colleagues, JAMA Internal Medicine, 2015
- NFPA 70, National Electrical Code
- Harvia: selecting heater power
- Sun Home Saunas: electrical requirements
- USDA Forest Service: Wood Handbook
- International ThermoWood Association
- CPSC recalls
- OSHA: recognized testing laboratories
- MedlinePlus: hypothermia
- CDC: Legionella hot tub guidance